Taylor 810 Series Original Service Instructions page 42

Auto gap grills
Hide thumbs Also See for 810 Series:
Table of Contents

Advertisement

CONTROLS AND SYSTEMS
Service Mode
To enter the Service mode, the control must be in the Off
or Idle mode. The Service mode cannot be entered if the
grill is in the Standby or Cook mode.
1. Press and hold the PROGRAM key for approximately
5 seconds.
2
2. The control will display the password entry screen.
Using the keyboard displayed on the control, enter
the service password TECH1 and press the OK key.
2-12
Figure 2-26
Figure 2-27
Model 810, 812, 820, 822, 828 Series
The following options are available in the Service mode:
GAP CALIBRATION
PROBE CALIBRATION
HEAT
TEST MODE
UPDATE FIRMWARE
SERVICE CONTACT
USER MANUAL BITMAPS
131074
UPPER PLATEN
AUTO CLOSE
EVENT LOG
SET TIME
SHOW MODE
GAP CALIBRATION
This option sets the gap offset between the upper platen
and the grill for all clam menu items. Press the GAP
CALIBRATION key to enter the Gap Calibration mode.
When the STANDBY button is pressed, the platen gap
will default to 0.255 in. in this mode.
The display will show a number and the Up and Down
arrows. The Up arrow key increases the offset and the
Down arrow key decreases the offset. This value is
131086
adjustable from -0.100 to 0.100. (Each increment
represents approximately one thousandth [.001] of an
inch.) Pressing the EXIT key exits this mode and saves
the offset setting.
The gap can only be calibrated when the grill and the
platen are at or above set point temperatures. If the grill
is not at set point temperature, TOO COOL is displayed.
Note: Heaters will cycle normally during this time.
See "Gapping Procedures" starting on page 2-24 for
complete gapping instructions.
Controls and Systems

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

812 series820 series822 series828 series

Table of Contents