6.2. Precautions for Direct Installation

It is necessary to provide a clearance of 50 mm or more in the horizontal direction and a
clearance of 100 mm or more in the upward direction near the controller.
Provide a ventilation space at the side of the controller so that the air vent
holes are not blocked. The space equal to the length of the legs should be
kept below the lower surface.
Failure to do so could cause the cooling performance to drop or to faults.
DO NOT stack the controllers.
DO NOT place any object on top of the controller.
50 mm or more
For vertical
placement
specification:
This side must face
downward.
TRANSPORTATION AND INSTALLATION MANUAL
!
CAUTION
100 mm or more
Fig. 6.2 Controller ventilation space
67
50 mm or more