3.2

Switch setting and display of the servo amplifier

Switching to the test operation mode and configuring network setting can be done with switches on the servo amplifier. The
network communication status and alarm status can also be checked on the display (3-digit, 7-segment LED) of the servo
amplifier.

Switches

If a metal screw driver contacts with the conductive areas, the switches may malfunction. Therefore, use an insulated screw
driver instead of the metal screw driver to operate rotary switches (SW1/SW2) and DIP switches (SW3).
If all the DIP switches (SW3) are turned "ON (up)", the servo amplifier is switched to the operation mode for manufacturer
setting and "off" will be displayed. The servo amplifier cannot be used in this mode. Thus, set the DIP switches (SW3)
correctly according to this section.
To apply the settings of all switches, cycle the control circuit power supply or reset the software.
The following explains the rotary switches (SW1/SW2) and DIP switches (SW3).
Switch identification
■1-axis servo amplifier
3-digit, 7-segment LED
Rotary switch (upper) (SW1)
■2-axis servo amplifier
3-digit, 7-segment LED
Rotary switch (upper) (SW1)
■3-axis servo amplifier
3-digit, 7-segment LED
Rotary switch (upper) (SW1)
3 STRUCTURE
40
3.2 Switch setting and display of the servo amplifier
DIP switch (SW3)
RUN
MS
ERR
NS
SFTY
Rotary switch (lower) (SW2)
DIP switch (SW3)
RUN
MS
ERR
NS
SFTY
Rotary switch (lower) (SW2)
DIP switch (SW3)
RUN
MS
ERR
NS
SFTY
Rotary switch (lower) (SW2)
ON
2
1
For manufacturer setting (SW3-2)
Test operation select switch (SW3-1)
ON
1
2 3 4
For manufacturer setting
Disabling control axis switch for B-axis (SW3-3)
Disabling control axis switch for A-axis (SW3-2)
Test operation select switch (SW3-1)
ON
1
2 3 4
Disabling control axis switch for C-axis (SW3-4)
Disabling control axis switch for B-axis (SW3-3)
Disabling control axis switch for A-axis (SW3-2)
Test operation select switch (SW3-1)

Hide quick links: