3.2
Switch setting and display of the servo amplifier
Network settings can be configured using switches on the servo amplifier. The network communication status and alarm
status can also be checked on the display (1-digit, 7-segment LED) of the servo amplifier.
Switches
If a metal screw driver contacts with the conductive areas, the switches may malfunction. Therefore, use an insulated screw
driver instead of a metal screw driver to operate the ID setting switches (SW1/SW2).
To apply the settings of all switches, cycle the power supply or reset the software.
The following explains the ID setting switches (SW1/SW2).
Switch identification
1-digit, 7-segment LED
ID setting switch (upper digit)
(SW1)
ID setting switch (lower digit)
(SW2)
ID setting switches (SW1/SW2)
The node address can be set with the ID setting switches (SW1/SW2) of the servo amplifier. SW1 indicates an upper digit and
SW2 indicates a lower digit of a hexadecimal.
To set the address to 02h, set the ID setting switches to the following positions.
The ID setting switches are set to 01h when shipped from the factory.
For how to set node addresses, refer to "Node address setting" in the following manual.
MR-JET-G-N1 User's Manual (Communication Function)
3 STRUCTURE
22
3.2 Switch setting and display of the servo amplifier