Danfoss VLT FC 103 Operating Manual page 84

Refrigeration drive
Hide thumbs Also See for VLT FC 103:
Table of Contents

Advertisement

Specifications
Normal overload
(Normal overload=110% current during 60 s)
Typical shaft output at 550 V [kW]
Typical shaft output at 575 V [hp]
Typical shaft output at 690 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V) [A]
Continuous (at 575/690 V) [A]
Intermittent (60 s overload) (at 575/690 V) [A]
Continuous kVA (at 550 V) [kVA]
Continuous kVA (at 575 V) [kVA]
Continuous kVA (at 690 V) [kVA]
Maximum input current
Continuous (at 550 V) [A]
Continuous (at 575 V) [A]
Continuous (at 690 V) [A]
Maximum number and size of cables per phase (E2h)
- Mains and motor without brake [mm
9
9
- Mains and motor with brake [mm
- Brake or regeneration [mm
Maximum number and size of cables per phase (E4h)
- Mains and motor [mm
- Brake [mm
2
- Load share or regeneration [mm
Maximum external mains fuses [A]
Estimated power loss at 600 V [W]
Estimated power loss at 690 V [W]
4)
Efficiency
Output frequency [Hz]
Heat sink overtemperature trip [°C (°F)]
Control card overtemperature trip [°C (°F)]
Power card overtemperature trip [°C (°F)]
Fan power card overtemperature trip [°C (°F)]
Active in-rush card overtemperature trip [°C (°F)]
Table 9.4 Technical Specifications, Mains Supply 3x525–690 V AC
1) American Wire Gauge.
2) For fuse ratings, see chapter 9.7 Fuses.
3) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies for
dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses can increase. LCP and typical control
card power consumptions are included. For power loss data according to EN 50598-2, refer to drives.danfoss.com/knowledge-center/energy-
efficiency-directive/#/. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for
slots A and B each add only 4 W.
4) Measured using 5 m shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy efficiency
class, see chapter 9.4 Ambient Conditions. For part load losses, see drives.danfoss.com/knowledge-center/energy-efficiency-directive/#/.
82
2
(AWG)]
2
1)
(AWG)]
2
1)
(AWG)]
2
1)
(AWG)]
(AWG)]
1)
2
1)
(AWG)]
2)
3), 4
3), 4
Danfoss A/S © 04/2018 All rights reserved.
VLT® Refrigeration Drive FC 103
1)
± 15% (tolerance relates to variety in voltage and cable conditions.) These
N710
NO
560
750
710
E2h/E4h
E2h/E4h
763
839
730
803
727
727
872
735
704
704
6x240 (6x500 mcm)
6x240 (6x500 mcm)
5x240 (5x500 mcm)
5x240 (5x500 mcm)
2x185 (2x350 mcm)
2x185 (2x350 mcm)
6x240 (6x500 mcm)
6x240 (6x500 mcm)
2x185 (2x350 mcm)
2x185 (2x350 mcm)
4x185 (4x350 mcm)
4x185 (4x350 mcm)
1200
10346
10066
0.98
0–590
110 (230)
110 (230)
80 (176)
80 (176)
85 (185)
85 (185)
85 (185)
85 (185)
85 (185)
85 (185)
N800
NO
670
950
800
889
978
850
935
847
847
1016
857
819
819
1200
12723
12321
0.98
0–590
MG16P222

Advertisement

Table of Contents
loading

Table of Contents