Connecting To Extractor System; Connecting To Compressed Air Supply; Connecting To The Power Supply; Drilling Spindles - Hettich BlueMax Mini Typ 3 Operating Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 43
Drill bits
The machine is intended for use with solid carbide drill bits in
a length of 57 mm and shaft diameter of 10 mm. Insert drill
bits all the way, chucking faces turned towards the threaded
studs, and tighten with the hexagon socket spanners.
Pay attention to the spindle turning direction!
If necessary, adjust the length of the drill bits at the adjust-
ment screws integrated in the drill-bit shaft.
Bohrbild
L
L
5,5
L
Fig. 17: Drilling pattern

Connecting to extractor system

Connect the machine to an extractor system.
It is compulsory to use flexible, fire-retardant hose
for connection to an extractor system.
Fit the extractor system's extraction hose to suction
connector
and secure this in place with a hose clamp.
1
The extractor system must have an airflow rate
of at least 20 m/s.
Extraction hose diameter: Ø 50 mm. Route extraction hose
so as not to exert strain on the suction connector!
Fig. 18: Suction extraction connector
32
L
21
R
L
32
52
1

Connecting to compressed air supply

To connect the machine to the compressed air supply
system, push the air supply line onto the air filter using
quick release connector
.
1
Recommended air pressure 6-7 bar, 100 PSI.
Fig. 19: Air filter unit with quick release connector

Connecting to the power supply

Connect to the power supply using a 16-ampere plug.
Before you do, have a qualified electrician ensure that the
socket is in proper working order.
Now connect the plug to the socket.
The machine is rated for a supply voltage of 400 volts.
(Other options are possible)
optional
(only with CE electrics)
CE:
1 and 2: br; 3 and 4: bl; PE: gr/ye
UL/CSA:
1, 2, 3 and 4: sw; PE: gr/ye
P = see order
U = see order
I = see order
n = 2800 rpm
BlueMax Mini
1 phase
Use an appropriate plug compliant with the DIN VDE or
IEC standard. An upstream fuse must be provided in the
mains power supply system.
Check motor turning direction. The drive spindles must turn
clockwise.
If the motor or spindles turns anticlockwise, you must reverse
the phases in the plug.
Danger from electric shock!
Working on live components in the improper manner
presents a danger to life!
Work on electrical equipment must only be carried out by
authorised electricians!
1
optional
(only with CE electrics)
CE:
1 and 2: gr; 3 and 4: br; 5 and 6: sw;
PE: gr/ye
UL/CSA:
1 and 2: rd; 3 and 4: br; 5 and 6: sw;
PE: or with gr/ye
P = see order
U = see order
I = see order
n = 2800 rpm
BlueMax Mini
3 phases
en