MAINTENANCE
RECOMMENDED FILLING INSTRUCTIONS FOR HYDRAULIC
RESERVIORS
When filling or checking the oil level, the unit should
be parked on a level surface., shut OFF, and allow
sufficient time to cool to ambient temperature. Use
caution when removing the pressurized breather.
Do not place face over opening when removing
breather.
If your reservior has two sight glasses:
The
reservior should be filled to the top of the lower
sight glass on the side of the tank. Do not overfill.
The reservoir has been overfilled when oil is visible
in the upper sight glass. If tank has too much oil, the
excess may be expelled through the pressurized
breather.
If your reservior has one sight glass/temperature
gage: The reservior should be filled to the center
of the sight glass on the side of the tank. Do not
over-fill. If the tank has too much oil, the excess
may be expelled through the pressurized breather.
DETAILED MAINTENANCE
REPLACING IN-TANK HYDRAULIC FILTER:
Loosen the four bolts on the top cover of the filter
housing. Turn cover counter-clockwise until cover is
free. Remove and replace filter. Replace top cover
and cover bolts in opposite order as removed.
Boom
Maintenance Section 4-11