Operating Specifications; Conformance To Specification (±3 [Sigma]); Accuracy; Temperature Limits - Emerson Rosemount WPG Reference Manual

Wireless pressure gauge with wirelesshart protocol
Hide thumbs Also See for Rosemount WPG:
Table of Contents

Advertisement

Reference Manual
00809-0100-4045, Rev AB
Rosemount 306 Integrated Manifolds
Reference the Rosemount Manifolds
Sheet
for shipping weights.
A.2 Operating specifications
A.2.1 Conformance to specification (±3
[Sigma])
Technology leadership, advanced manufacturing
techniques, and statistical process control ensure
specification conformance to at least ±3 .
A.2.2 Accuracy
ASME B40.1 – Grade 2A (0.5% of span)
A.2.3 Temperature limits
Ambient
-40 to 185 °F (-40 to 85 °C)
Storage
-40 to 185 °F (-40 to 85 °C)
Process
-40 to 250 °F (-40 to 121 °C)
A.2.4 Electrical connections/battery
Replaceable, non-rechargeable, 3.6V primary cell,
lithium-thionyl chloride battery
10-year battery life at reference conditions
A.2.5 Overpressure limit
Maximum
Scale range
working
pressure
5 – 30 psi
30 psi
(0.35 – 2 bar)
(2 bar)
31 – 150 psi
150 psi
(2.1 – 10.3 bar)
(10.3 bar)
151 – 800 psi
800 psi
(10.4 – 55.1 bar)
(55.1 bar)
801 – 4,000 psi
4,000 psi
(55.2 – 275 bar)
(275 bar)
1.
Process temperatures above 185 °F (85 °C) require de-rating the
ambient limits by a 1.5:1 ratio.
2.
220 °F (104 °C) limit in vacuum service; 130 °F (54 °C) for pressures
below 0.5 psia.
3.
Reference conditions are 70 °F (21 °C), Stable operating pressure
with periodic changes, transmit rate of once per minute, and routing
data for three additional network devices.
42
Product Data
(1)(2)
(3)
Maximum
overpressure
limit
750 psi
(51.7 bar)
1,500 psi
(103.4 bar)
1,600 psi
(110.3 bar)
6,000 psi
(413.7 bar)
Specifications and Reference Data
A.2.6 Burst pressure limit
Up to 11,000 psi (758 bar)
A.2.7 Minimum span limits for percent of
range engineering unit
The maximum rangedown is 10:1. The device maintains
reference accuracy specification up to 6:1 rangedown. After
6:1 rangedown the reference accuracy decreases to 1% of
span.
Scale range
Span (6:1 ratio)
5 – 30 psi
5 psi (0.34 bar)
(0.35 – 2 bar)
31 – 150 psi
25 psi (1.72 bar)
(2.1 – 10.3 bar)
151 – 800 psi
134 psi (9.24 bar)
(10.4 – 55.1 bar)
801 – 4,000 psi
667 psi (45.99 bar)
(55.2 – 275 bar)
A.2.8 Ambient temperature effect per 18 °F
(10 °C)
Scale range
Wireless pressure gauge
Up to 4,000 psi (275 bar)
Wireless pressure gauge with remote seal
Up to 4,000 psi (275 bar)
A.2.9 Digital zero trim
An offset adjustment to compensate for mounting position
effects, up to 5% of Span
A.2.10 Humidity limits
0-95% relative humidity
A.2.11 Electromagnetic compatibility (EMC)
Meets all relevant requirements of CE 61326-1: 2006.
A.2.12 Status indication
Device status is indicated by local LED. Reference Wireless
Pressure Gauge Quick Start Guide (document number
00825-0100-4045) for further detail.
March 2016
Minimum span
(10:1 ratio)
3 psi (0.21 bar)
15 psi (1.03 bar)
80 psi (5.51 bar)
400 psi
(27.5 bar)
Ambient temperature
effect
±0.3 of span
See Instrument Toolkit
software.