  • Page 1 Quick Start Guide 00825-0100-4145, Rev BB February 2019 ™ Rosemount Smart Pressure Gauge...
  • Page 2: Table Of Contents

    Failure to follow these installation guidelines could result in death or serious injury. Ensure only qualified personnel perform the installation. Contents Required equipment........3 Installation Procedure........8 What’s in the box........... 4 Troubleshooting.......... 12 Optional: Power/device check......6 Product Certifications........13 Optional: Normal range indication option..7 Emerson.com/Rosemount...
  • Page 3: Required Equipment

    February 2019 Quick Start Guide Required equipment Figure 1-1: Anti-seize paste or PTFE tape (for NPT threaded connection) Figure 1-2: Standard tools (e.g., screwdriver, wrench, pliers) Quick Start Guide...
  • Page 4: What's In The Box

    What’s in the box Smart Pressure Gauge Quick Start Guide The following options are also available and will ship with the Rosemount Smart Pressure Gauge if ordered. Rosemount 306 Integral Manifold (model B4 bracket (model code B4) code S5) Emerson.com/Rosemount...
  • Page 5 February 2019 Quick Start Guide Rosemount 1199 Seal(model code S1) Product Certification Q4: Calibration Cert QG: Calibration Cert and GOST Verification Cert QP: Calibration Cert and Tamper Evident Seal Q8: Material Traceability cert per EN 102043.1 Q15: Cert of Compliance to NACE MR0175/ISO 15156 for wetted materials Q25: Cert of Compliance to NACE MR00103 for wetted materials...
  • Page 6: Optional: Power/Device Check

    Quick Start Guide February 2019 Optional: Power/device check The device is designed to be installation-ready. Procedure 1. To check device battery prior to installation, perform Turn on device 2. Slide the ON/OFF switch to the OFF position until ready for use. Emerson.com/Rosemount...
  • Page 7: Optional: Normal Range Indication Option

    February 2019 Quick Start Guide Optional: Normal range indication option Important • The stickers are intended to be installed on the dial only and should not be applied on the inside or outside of the housing cover. • Stickers should be applied in an environment where the ambient temperature is above 50°F (10°C) Procedure 1.
  • Page 8: Installation Procedure

    The vent path is between the housing and sensor. CAUTION Keep the vent path free of any obstruction, including but not limited to paint, dust, and lubrication by mounting the device so the process can drain away. Emerson.com/Rosemount...
  • Page 9 February 2019 Quick Start Guide Figure 5-1: Low Side Pressure Port A. Low side pressure port (atmospheric reference) Turn on device Check to ensure the device and battery are working properly. Procedure 1. Twist the cover counterclockwise to remove it. 2.
  • Page 10 1. Turn on the Field Communicator. 2. From the Main menu, select the HART symbol. Eliminate mounting effects Devices are factory-calibrated. Once installed, it is recommended to perform this step to eliminate potential error caused by mounting position or static pressure. Emerson.com/Rosemount...
  • Page 11 February 2019 Quick Start Guide Note See the Rosemount Smart Pressure Gauge Reference Manual for the following: • Using AMS Configurator • Sensor trim function on absolute gauge Procedure 1. Vent the device. 2. Connect the Field Communicator. 3. From the HOME screen, enter the HART Fast Key sequence. Device dashboard Fast Keys 2, 1, 1 4.
  • Page 12: Troubleshooting

    If the mounting effects have not been eliminated after completing, perform this alternative procedure for verifying the pressure value. Procedure 1. From the HOME screen, enter the HART Fast Key sequence. Device dashboard Fast 2, 2, 1, 1, 1 Keys 2. Follow the commands to perform the procedure. Emerson.com/Rosemount...
  • Page 13: Product Certifications

    A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount. Ordinary Location Certification from CSA The product has been examined and tested to determine that the design...
  • Page 14 2. The measured capacitance between the equipment enclosure and metallic inline sensor module is 4.7pF. This must be considered only when the SPG is integrated into a system where the process connection is not grounded. Emerson.com/Rosemount...
  • Page 15 February 2019 Quick Start Guide 3. Do not change the battery when an explosive atmosphere is present. 4. Only replace battery with Rosemount Part No. 00G45-9000-0001. International IECEx Intrinsic Safety Certificate: IECEx BAS 16.0012X Standards: IEC 60079-0: 2011, IEC 60079-11: 2011 Markings: Ex ia IIC T4 Ga, T4 (–40 °C ≤...
  • Page 16: Eu Declaration Of Conformity

    Assumption of conformity is based on the application of the harmonized standards and, when applicable or required, a European Community notified body certification, as shown in the attached schedule. Vice President of Global Quality (function name - printed) (signature) 1-Feb-19 Chris LaPoint (name - printed) (date of issue) Page 1 of 3 Emerson.com/Rosemount...
  • Page 17 February 2019 Quick Start Guide EU Declaration of Conformity No: RMD 1108 Rev. E EMC Directive (2014/30/EU) Models WPG & SPG Harmonized Standards: EN 61326-1: 2013 Radio Equipment Directive (RED) (2014/53/EU) Model WPG (Wireless Pressure Gauge only) Harmonized Standards: EN 300 328 V2.1.1 EN 301 489-1 V2.2.0 EN 301 489-17: V3.2.0 EN 61010-1: 2010...
  • Page 18 SGS FIMCO OY [Notified Body Number: 0598] P.O. Box 30 (Särkiniementie 3) 00211 HELSINKI Finland ATEX Notified Body for Quality Assurance SGS FIMCO OY [Notified Body Number: 0598] P.O. Box 30 (Särkiniementie 3) 00211 HELSINKI Finland Page 3 of 3 Emerson.com/Rosemount...
  • Page 19 February 2019 Quick Start Guide Rosemount SPG China RoHS List of Rosemount SPG Parts with China RoHS Concentration above MCVs / Hazardous Substances Hexavalent Polybrominated Polybrominated Part Name Lead Mercury Cadmium Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (Cr +6) (PBB) (PBDE) Electronics...
  • Page 20 The Emerson logo is a Facebook.com/Rosemount trademark and service mark of Emerson Electric Youtube.com/user/ Co. Rosemount is mark of one of the Emerson RosemountMeasurement family of companies. All other marks are the Google.com/+RosemountMeasurement property of their respective owners.