Boot Messages

Many boot messages are "normal" messages, and are described here
simply for information. Others are error messages, and include rec-
ommended action. After taking the recommended action for an error
message, reboot the node. If the problem has not been corrected,
contact
Cabletron Systems Technical
Boot messages are listed below in alphabetical order.
Boot Time: nn/nn/19nn–nn:nn:nn
Meaning: This is the date and time of the current boot-up.
Action:
None.
Buffers: Xmt count "n," Xmt size "n," Rcv count "n," Rcv size "n"
Meaning: These values denote the numbers and sizes of the
pre-fetch buffers used by the LAN interface.
Action:
None.
Checking configuration files
Meaning: Self-explanatory. The software checks to make sure
all files are valid.
Action:
None.
Community Table file Read Error, System may not Boot Correctly
Meaning: There is a error in the database file COMPAR.DAT.
Action:
Delete the file and create a new one by configuring
new SNMP Community Table records (described
in the User Guide).
Conversion Error
Meaning: The database file specified in the message dis-
played before this one (see
) was not successfully converted to the new
file ...
release of FRX4000 software.
Action:
If the file is X25REC.DAT (node parameters), a new
default file will automatically be created. If an error
occurs in any other file, delete the file and create a
Diagnostic Procedures
Support.
Converting (FILENAME)
2-5