Table 4-1 LANVIEW LEDs
LED
Color
CPU
Off
Red
Amber
Green
State
Power disconnected.
Solid. Boot-up failed.
Blinking. Diagnostics have
failed.
Solid. Diagnostics are running. If the LED remains amber for more than
Blinking. Code image is being
downloaded.
Solid. System is fully
functional.
Blinking. Boot-up in process.
Recommended Action
If the LED remains off after connecting AC
power or DC power from an RPS, check
the following:
1. Make sure there is power at the power
source (AC source and RPS if
applicable).
2. Replace the power cord with a known
good one or check the continuity of the
power cord.
3. If the SecureStack A2 still does not
power up, the system may have a fatal
error. Contact Enterasys Networks for
technical support.
If the LED remains red for several
minutes, the system may have a fatal
error. Contact Enterasys Networks for
technical support.
Contact Enterasys Networks for technical
support.
several minutes, contact
Enterasys Networks for technical support.
None.
None.
None.