3.5.1.2
Removing the Side Clip GBIC
CAUTION: Do NOT remove a GBIC from a slot without unlocking the tabs. This can
damage the GBIC.
The GBIC, 1G-2GBIC, and 1G58x-09 are sensitive to static discharges. Use an
antistatic wrist strap and observe all static precautions during this procedure. Failure to
do so could result in damage to the GBIC, 1G-2GBIC and the 1G58x-09. Always leave
the GBIC in the antistatic bag or an equivalent antistatic container when not installed.
To remove the GBIC from the 1G-2GBIC, proceed as follows:
1. Attach the antistatic wrist strap (refer to the instructions in the antistatic wrist strap package)
before removing the GBIC.
2. Remove any cables connected to the GBIC.
3. Refer back to
Figure
4. Squeeze both locking tabs
GBIC out of the port.
5. If storing or shipping the GBIC, insert the dust protector into the GBIC to protect the fiber ports.
3.5.2
Locking Bar GBICs
This section describes how to install and remove GBICs that are equipped with a metal locking bar.
Refer to
Appendix C
CAUTION: This section applies only to GBICs equipped with a metal locking bar.
Damage can result to the GBIC and 1G-2GBIC if the directions in this manual are not
followed carefully.
The GBIC, 1G-2GBIC, and 1G58x-09 are sensitive to static discharges. Use an
antistatic wrist strap and observe all static precautions during this procedure. Failure to
do so could result in damage to the GBIC, 1G-2GBIC, or 1G58x-09. Always leave the
GBIC in the antistatic bag or an equivalent antistatic container when not installed.
3-4. Locate the locking tabs
➆
in towards the center of the GBIC
for GBIC cable specifications.
Removing the Side Clip GBIC
➆
on the side of the GBIC
➀
and hold, and then pull the
Hardware Installation
➀
.
3-9