Guidelines for Rackmount Installation
Figure 3-8 Clearance Required for Tabletop or Shelf Installation
À
➀
213 cm (7 ft)
➁
15 cm (6.0 in)
3.7.1
Rackmount Installation
To install the device in a 19-inch rack, you need the following items shipped with the device.
•
A strain-relief bracket, four M4 x 6 mm pan-head screws, and tie wraps
•
Two rackmount brackets and mounting screws
Also needed are four user-supplied screws to attach the device to a standard 19-inch rack.
3.7.1.1
Guidelines for Rackmount Installation
The installation site must be within reach of the network cabling and meet the requirements listed
below:
•
Appropriate grounded power receptacles must be located within seven feet of the location.
•
A temperature of between 5°C (41°F) and 40°C (104°F) must be maintained at the installation
site with fluctuations of less than 10°C (18°F) per hour.
3-16
Hardware Installation
Ã
➂
➃
Â
53 cm (21.0 in)
57 cm (22.5 in)
Á