Configuration For Site "Remote - Cabletron Systems CyberSWITCH CSX5500 Quick Start Manual

Central site remote access switch
Hide thumbs Also See for CyberSWITCH CSX5500:
Table of Contents

Advertisement

QUICK START
Enter lanport1 for the port name.
Enter 1 for the LAN port number.
Select the Extended network type (the default).
Enter 10-13 for the network range.
Accept the default of none for the suggested AppleTalk address.
Enter Engineering as the port's default zone name.
Enter Marketing as the second zone name.
c.
Under AppleTalk Port Information, configure a WAN (Remote LAN) port:
Select the WAN (Remote LAN) port type.
Enter Extended for Remote's network type (the default).
Enter 45-50 as the destination network range (Remote's network range).
Accept the default of none for the suggested AppleTalk address.
Enter Remote.Engineering as Remote's default zone name.
Enter Remote.Marketing as Remote's second zone name.
3.
Under Security, select System Options and Information, then under System Information:
a.
Set your System Name (Central). This matches up with Central device information
configured on Remote.
b. Set your System Secret (Central_S). This matches up with Central device information
configured on Remote.
4.
Under Security, select Device Level Databases, select On-node Device Entries, then add a device
where the Device Name (Remote) must match the system name on Remote. When you add the
device you must then enter the following information:
a.
Under ISDN Information select ISDN Line Protocol, then select PPP.
b. Under Authentication you must:
Change CHAP Secret so that it matches Remote's System secret (Remote_S).
Optional: Configure Calling Line Ids (if Calling Line Id security was enabled).
c.
Under Bridge Information you must:
Make sure that Bridging is enabled
Enter the AppleTalk Network Number 45.
C
S
ONFIGURATION FOR
ITE
The configuration on Remote to allow AppleTalk Routing from Central using PPP is as follows:
1.
Start QuickSET and select Custom.
2.
Configure the CSX100 system information.
a.
Accept the Local Ethernet IP Address. Click Next.
b. Set your CyberSWITCH Name (Remote) and System Password (Remote_S).
c.
Select your switch type.
d. Enter the directory number for the CSX100 (13135552222). Click Next twice.
3.
Define Central as a remote connection.
a.
Click Add Remote, enter Central, and click OK.
b. Set the password. Click Remote's Password and enter Central_S twice for confirmation.
c.
Define Central's phone settings. Enter 13135551111.
d. Optional: Define Caller ID Numbers if Caller ID Security was enabled. Click Next.
e.
Enable Inbound and Outbound Bridging by clicking in the boxes.
4.
Click Save.
30
CyberSWITCH
"R
"
EMOTE

Advertisement

Table of Contents
loading

Table of Contents