6000 Series Wiring Diagrams
Door is normally closed.
Activating switch will open door.
Door will close after hold open time delay has elapsed.
If door is closed and 585 Presence Detector senses
something in the opening, door will not open when
activated.
If door is at open position and 585 Presence Detector
senses something in the opening, door will not close
after hold open time delay has elapsed.
Once opening is clear, door will close after hold open
time delay has elapsed again.
NOTE: For Low Energy Operators, Presence Detectors and/
or sensors CANNOT be used to activate an opening cycle of
the door.
To activate presence detector functionality:
Use instructions provided with 585 sensor to program
and make any necessary adjustments to sensor.
Copyright © 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1043-020 Rev 1 05/21
585 Presence Detector on Single Door Opening
585 Presence Detector
mounted to / above frame
(on single opening)