EIA-232

Table A-10
shows the connector number, cable assembly description, and connector type.
Connector Number
Table A-11
provides pin assignments for the EIA-232 interface cable.
Connector 1 EIA-530A ALT A
DIRECT
MNEMONIC
TO
BA
DCE
BB
DTE
CB
CA
DCE
DB
DTE
DD
DA
DCE
CE
DTE
RL
DCE
LL
TM
DTE
CC
CD
DCE
AC
AB
CSX200 Installation Guide
Table A-10 EIA-232 Interface
Cable Assembly Description
1
EIA-530A ALT A to EIA-232
2
Table A-11 EIA-232 Interface Cable Pin Assignment
NAME
Transmit Data
Receive Data
Clear to Send
Request to Send
Transmit Signal Timing
Receive Signal Timing
Transmit Signal Timing
Ring Indicator
Remote Loopback
Local Loopback
Test Mode
DCE Ready
DTE Ready
SHIELD
Signal Common
Signal Common
Connector Type
Sub DB 26-pin male
DB-25 pin male
Connector 2 EIA-232
PIN PIN
NAME
2
2
Transmit Data
3
3
Receive Data
5
5
Clear to Send
4
4
Request to Send
Transmitter Signal
15
15
Timing
Receiver Signal
17
17
Timing
Transmitter Signal
24
24
Timing
22
22
Ring Indicator
Loopback
21
21
Maintenance
18
18
Local Loopback
25
25
Test Indicator
6
6
DCE Ready
20
20
DTE Ready
1
23
7
Signal Common
7
7
Signal Common
WPIM-SY
DIRECT
MNEMONIC
TO
DCE
BA
BB
DTE
CB
DCE
CA
DB
DTE
DD
DCE
DA
DTE
CE
RL
DCE
LL
TM
DTE
CC
DCE
CD
AB
AB
A-7