Series 90 Setup Manual
APPENDIX A - SCANNER RESISTOR BANK
A bank of resistors is used to test the scanner board and scanner control board. The resistors can
be soldered directly to a mating connector, or optional calibration boards may be used. The low-
voltage testers use thirteen resistors and the high-voltage testers use fourteen. The values and
corresponding connector locations are shown below.
Ω
R1 - 3.32
Ω
R2 - 39.2
Ω
R3 - 82.5
Ω
R4 - 392
Ω
R5 - 1k
R6 - 3.92k
R7 - 12.1k
R8 - 43.2k
Ω
R9 - 121k
R10 - 267k
R11 - 475k
R12 - 825k
R13 - 3.32M
Low-voltage Resistor Bank
The 100 M
1
5
9
13
17
21
Ω
25
Ω
29
Ω
33
37
Ω
41
Ω
45
Ω
49
Ω
53
64
resistor, R14, must be rated at 1500 vdc or higher.
R1 - 3.32
R2 - 39.2
R3 - 82.5
R4 - 392
R5 - 1k
R6 - 3.92k
R7 - 12.1k
R8 - 43.2k
R9 - 121k
R10 - 267k
R11 - 475k
R12 - 825k
R13 - 3.32M
R14 - 100M
High -voltage Resistor Bank
Note:
1
Ω
5
Ω
9
Ω
13
J1
Ω
17
Ω
21
Ω
25
Ω
29
Ω
1
Ω
5
Ω
9
Ω
13
J2
Ω
17
Ω
21
Ω
25
32
Page 55