Page 40
Series 90 Setup Manual
DIAGNOSTIC TESTS
Diagnostic tests can be performed on all Cablescan testers that are capable of interfacing to
TestRite software. TestDiag automatically configures the Test Selection Window for, and
provides tests based on, the type of tester selected from the Tester/Settings window. Functions
that do not apply to the situation or tester type at the time are grayed out and cannot be selected.
Note:
Interface cables between the tester and the test fixture
must be disconnected while running diagnostics.
TEST SELECTION WINDOW
The Test Selection Window comprises check boxes and radio buttons to select the tests to be
performed on the type of tester selected. (See previous section for selecting the type of tester.)
Since TestMate, Model 64, Model 64x2, Model 128/PC, Model 256/PC, and Model 512 have
built-in self-test routines, all of their check boxes on the TestDiag screen are grayed out. The
check boxes on the TestDiag screen pertain only to the Series 90 systems. The screen is divided
into two types of tests: low voltage and high voltage. Low-voltage Tests are performed on both
low-voltage and high-voltage Series 90 testers. High-voltage Tests are special tests that are
performed on only the high-voltage Series 90 testers. When the tester type is set to Series 90, the
High-voltage Tests are grayed out. When the tester type is set to Series 90HV, none of the Test
check boxes are grayed out. However, a group of tests, Low Voltage or High Voltage, can be
disabled (grayed out) by unchecking the Enable check box in the specific group.
(Test Selection Window)