6.4. SYSTEM OPTIONS
6.4.1.
Show failures history with SYSTEM diode
Selecting this option indicates that a fault occurred in the system and be completed. This
condition will be indicated by flashing SYSTEM LED on the keyboard KP16 until cleared
the fault memory.
6.4.2.
Ignore ATS failure
Selecting this option turns off signaling a loss of communication with the server on KP16
keypad.
6.4.3.
Turn automatic override for failure off
Selecting this option enables the system fault signal when arming.
6.4.4.
Access to alarm and fault memory requires authorization
Selecting this option enables limitation to access to alarm memory and fault memory.
Checking alarm memory and fault memory will be available only after entering user code.
This option must be enabled in order to comply with EN 50131 standard requirements for
Grade 2.
CPX200NWB ALARM CONTROL UNIT – INSTALLER MANUAL
72 / 118