6.3.1.3. Interlocking
The option allows interlocking any input line, which means that any changes of state
at this input are ignored and not reported to monitoring station.
You can set the set permanently blocking input ("Permanent"), or turn on the
blocking after a given number of input violations.
If you select "After time for exit", the input line will be blocked if the line was violated
when arming. In this case, an event about blocked line will be generated, which
allows to inform the monitoring station about the problem with the line. This lock will
last until disarming. If the input is selected as the "Alarm after time for exit", then
"Interlocking after time for exit" has priority - the zone will be blocked and will not
generate an alarm.
If the line is set to "After time for exit" and is violated or sabotaged after the time for
exit, then is automatically blocked (bypass is activated). User can unlock the input by
use the function 50 # (block inputs).
6.3.1.4. Sensitivity
That parameter defines a minimum time the change must maintain at the particular
zone, to be detected by a transmitter. Default factory setting of the parameter is
400 ms.