partition can be given subsequently or in a form of series of service functions that configure
one partition-related parameter. Codes of partition configuration functions are defined as
per the following pattern:
where:
XX –
determines the number of partition from 01 to 02; entering number 00 will change
the parameters for both partitions,
Y –
number of parameter related to a selected partition:
 0 – complex function, the initiation of which configures the parameters listed below
as another set of parameters;
 1 – zones belonging to partition (BIT type parameter, zones 10 – 16 may be set by
long press the keys 0 – 6),
 2 – outputs belonging to partition (BIT type parameter),
 3 – time for leaving the partition in seconds (DEC type parameter),
 4 – alarm time in the partition in seconds (DEC type parameter),
5 – partition options (BIT type parameter):
o 1 – Quiet signalling of time for entering (during counting the time for leaving, the
buzzer in a keypad is not active)
o 2 – Quiet signalling of time for leaving (during counting the time for leaving, the
buzzer in a keypad is not active)
 6 – auto-arming time (DEC type parameter, time of day written in the 24-hour
notation in the form HHMM),
 7 – auto-arming option (BIT type parameter):
o 1 – auto-arming activation/deactivation
 8 – auto-disarming time (DEC type parameter, time of day written in the 24-hour
notation in the form HHMM),
 9 – auto-disarming option (BIT type parameter):
o 1 – auto-disarming activation/deactivation
Notes:
Execution of complex function 3006 (auto-arming time for all paritions) will copy
activation/deactivation option from the first partition to the second partition.
Execution of complex function 3007 (auto-arming activation/deactivation for all paritions)
will copy auto-arming time from the first partition to the second partition.
Execution of complex function 3008 (auto-disarming time for all paritions) will copy
activation/deactivation option from the first partition to the second partition.
Execution of complex function 3009 (auto-disarming activation/deactivation for all
paritions) will copy auto-disarming time from the first partition to the second partition.
If the time in the device is set forward (eg. when the time is changed to Daylight saving
time), and arming or disarming time is in the period which has been ommited, then the
hour will be not used. Eg. If the auto-arming time is set to 2:30, and time was changed
forward from 2:00 to 3:00, the control panel will not arm.