EBS CPX200NWB Installation And Programming Manual page 11

Alarm control unit
Table of Contents

Advertisement

NOTE: Antenna shouldn't be instaled on alarm central case or in close
range to wireless recivers. It could decrease the signal range.
2. Slot of SIM card
The control unit is equipped with integrated GSM/GPRS/SMS transmitter. SIM card with
active GPRS transmission is necessary to communicate with the server. The card shall be
installed in the slot indicated in the drawing.
NOTE: Before you insert the card, make sure that PIN code
authorization is deactivated, or PIN code is compliant with the code
programmed in the control unit. Default factory PIN code of the control
unit is 1111.
3. "STATUS" LED
Yellow LED diode. For the detailed description of "STATUS" LED operation, please refer to
chapter 7.
4. "ERROR" LED
Red LED diode. For the detailed description of "ERROR" LED operation, please refer to
chapter 7.
5. "OK" LED
Green LED diode. For the detailed description of "OK" LED operation, please refer to chapter
7.
6. "CONF" programming connector
"CONF" IDC10 connector allows the control unit configuration using dedicated GD-PROG
programming device and any computer equipped with RS232 port.
7. "PROG" Button for default settings restoration
Pressing the button for 10s during connecting the control unit with power supply will delete
all users and restore the default admin and instaler code. Default admin code is 1111,
default instaler code is 2222.
8. "START" button for battery activation of control unit without the mains
power supply
If the control unit is activated in the situation of power supply fault, press the button after
connecting the unit to the battery.
9. Screw terminals of the control unit
For detailed information on feeding, input and output connectors, please refer to chapter
3.3.
10.
Assembly holes of the control unit (132x61mm hole span)
CPX200NWB ALARM CONTROL UNIT – INSTALLER MANUAL