form of series of service functions that configure one zone-related parameter. Additional
configuration of wireless zones is described in item 4.3.9.
Codes of zone configuration functions are defined as per the following pattern:
where:
XX –
determines the number of zone from 01 to 16; entering number 00 will change the
parameters for all zones in the system,
Y
– number of parameter related to a given zone:
 0 – complex function, the initiation of which configures the parameters listed below
as another set of parameters;
1 – type of zone response (DEC type parameter):
o 0 – instant
o 1 – delay
o 2 – 24h burglary
o 3 – arming/disarming
o 4 – 24h tamper
o 5 – interior delayed
o 6 – 24h burglary silent
o 7 – 24h fire
o 8 – perimeter
o 9 – perimeter exit
2 – delay in seconds for the circuit of selected "delay" response type (DEC type
parameter). For other response types the parameter is irrelevant.
3 – operation mode (DEC type parameter):
o 0 – unused circuit
o 1 – NC mode
o 2 – NO mode
o 3 – EOL/NC mode
o 4 – EOL/NO mode
o 5 – DEOL/NC mode
o 6 – DEOL/NO mode
o 7 – Wireless mode
4 – number of alarms after which the zone will be automatically blocked until re-
arming (DEC type parameter). If 0, zone will not be blocked.
5 – zone options (BIT type parameter):
o 1 – circuit ignored during arming – i.e. can be violated during partition arming
(e.g. delay circuits shall be set to that option)
o 2 – generates alarm when violated after arming
o 3 – interlocking the zone (bypassing zone) if the zone violated when arming
(parameter "After time for exit")
6 – sensitivity in milliseconds, i.e. after what time the input is considered to change
its status – default value; 400ms
CPX200NWB ALARM CONTROL UNIT – INSTALLER MANUAL