Metallic Access Unit Testing Capabilities; Introduction; Initiating Mtau Test Access; Conn-Jack-T1 - ADTRAN H2TU-C Installation And Maintenance Practice

Asynchrononous line cards for litespan channel bank assemblies using narrowband and wideband pairs
Table of Contents

Advertisement

Metallic Access Unit Testing Capabilities

INTRODUCTION

This appendix describes the testing functionality available for the Litespan H2TU-C via the
MTAU unit. For a complete description of the MTAU unit, refer to Alcatel document Common
Equipment Unit Descriptions, OSP 363-405-250.
The functionality of the SPLIT and MON features detailed in this
document supersedes that shown in the OSP 363-405-250.

INITIATING MTAU TEST ACCESS

CONN-JACK-T1

The Connect T1 Jack command connects a T1 or HDSL facility to the MTAU via the channel
bank test bus.
Input Format:
CONN-JACK-T1:<TID>:<AID>:<CTAG>::<MD>;
AID = Access ID of the unit to be connected to the MTAU
MD = Mode (SPLIT or MON)
Example: CONN-JACK-T1::COT-1-15:::SPLIT;
To use SPLIT mode, a facility must be out of service for mainte-
nance or out of service for memory administration.
61221002L1-5F
Appendix C
NOTE
NOTE
C-1