Appendix B, Litespan H2TU-C Provisioning Tutorial - Provisioning the Litespan H2TU-C via TL1 Commands
<IGLOC>
<LINECDE>
<LP>
<PTTRN>
<SEQ>
<YEL>
<PST>
<SST>
System Response:
/* <number> T1 Facilities Edited */
* Facility must be OOS to modify FMT field. Values other than AUTO are valid for DS1U, T1U, HT1U, or DS1M.
AUTO is valid only for AHDSL or AHDXL. When CLEAR is used, LINECDE must be AMI.
16. Enter a T1 cross-connection between the H2TU-C and a ADS1U in the CBA by entering
the following command:
ENT-CRS-T1::<Node 1 T1 Access ID>,<Node 2 T1 Access ID>;
(See
Table B-6
for details on the ENT-CRS-T1 command.)
61221002L1-5F
Table B-5. Edit T1 (Continued)
Command: ED-T1
Interface group
Not applicable.
location
Line code
Options: AMI, B8ZS, BIT7, AUTO
Line Powering
Not required.
Idle pattern
The PTTRN field indicates the detectable idle pattern.
The values are hex values: 0F, 17, 1B, 77, 7F, 88, 8F,
FF.
Valid for ADS1U, AT1U, AHDSL, and AHDXL.
Channel sequence
Not required.
Yellow alarm
The ability to recognize/transmit a yellow signal, and
generate a yellow alarm. Options: Yes or No.
Valid for T1U, HT1U, DS1U, AHT1U, AHDSL, and
AHDXL.
Primary service
No user entry needed.
state
Default = no change.
Secondary service
No user entry needed.
state
Default = no change.
B-11