Table B-6. Enter T1 Cross-Connection - ADTRAN H2TU-C Installation And Maintenance Practice

Asynchrononous line cards for litespan channel bank assemblies using narrowband and wideband pairs
Table of Contents

Advertisement

Litespan H2TU-C Installation and Maintenance Practice
Function:
Adds a T1 cross-connections to the database.
Input format:
ENT-CRS-T1:<TID>:<FROM>,<TO>:<CTAG>::::<PST>,<SST>;
Example:
ENT-CRS-T1::COT-1-10,COT-OCE-1-27;
Menu Access: Main Menu → 3. Provisioning Menu → 2. Cross-Connection Menu → 12. ENT-CRS-T1
Code
<TID>
<FROM>
<TO>
<CTAG>
<GB>
<CB>
<SB>
<PST>
<SST>
System Response:
For end-to-end cross-connections:
"<From AID>,<From-VT AID>,<To-VT AID>,<To AID>"/* <number> T1 Cross-Connections Entered */
For half cross-connections:
"<From AID>,<To AID>"/* <number> T1 Cross-Connections Entered */
17. Modify the provisioning data for the H2TU-C to set the Line Code parameter to B8ZS with
the following command:
ED-T1::<TERMINAL>-<BANK>-<SLOT>::::LINECDE=B8ZS;
(See
Table B-5
for details on the ED-T1 command.)
B-12

Table B-6. Enter T1 Cross-Connection

Command: ENT-CRS-T1
Parameter Usage
Definition
Description
Target ID
No user entry needed.
Default = connected terminal.
From AID
Enter <TERMINAL>-<BANK>-<SLOT> of the cross-
connection origin. Grouping and ranging are supported.
Example: RT2-1-12
To AID
Enter <TERMINAL>-<BANK>-<SLOT> of the cross-
connection destination. If used, the number of circuits
specified must equal the number specified by FROM
AID. Grouping and ranging are supported.
Example: RT2-1-27
Correlation tag
No user entry needed.
Default = 0.
General block
Parameter not allowed.
Common block
Parameter not allowed.
Specific block
Parameter not allowed.
Primary service
Options: IS or OOS.
table
Default = no change.
Secondary service
Options: RDLD or NOT-RDLD.
table
Default = no change.
61221002L1-5F

Advertisement

Table of Contents
loading