Initialize T1 Registers; Table B-9. Initialize T1 Register - ADTRAN H2TU-C Installation And Maintenance Practice

Asynchrononous line cards for litespan channel bank assemblies using narrowband and wideband pairs
Table of Contents

Advertisement

Appendix B, Litespan H2TU-C Provisioning Tutorial - Selected TL1 Commands for Provisioning, Maintenance, and Testing
<THLEV>
<TMPER>
<PST>
<SST>
System Response:
/* <number> T1 Grade Of Service Tables Edited */

Initialize T1 Registers

To reset T1 performance-monitoring registers to zero, use the command INIT-REG-T1. The
selection of appropriate parameter options will depend upon the Company-specific require-
ments.
(See
Table B-9
for details on this command.)
Function:
Resets the specified performance-monitoring register contents to zero. This command
affects only the current state of the register; data recorded for previous time periods is
unaffected.
Input format:
INIT-REG-T1:<TID>:<AID>:<CTAG>::<MONTYPE>,,<LOCN>,,<TMPER>;
Example:
INIT-REG-T1::COT-1-12:::CVL,,,,1-HR;
Menu Access: Main Menu → 2. Maintenance Menu → 20. T1 Maintenance Menu → 5. INIT-REG-T1
Code
<TID>
<AID>
<CTAG>
61221002L1-5F
Table B-8. Edit T1 Grade of Service (Continued)
Command: ED-GOS-T1
Threshold level
Time period
Primary service
state
Secondary service
state

Table B-9. Initialize T1 Register

Command: INIT-REG-T1
Parameter Usage
Definition
Target ID
Access ID
Correlation tag
Each monitored type has its own threshold level.
Default = no change.
Used to specify the time period for collection of GOS
data.
Options: 15-MIN, 1-DAY. Default = 15-MIN
Parameter not allowed.
Parameter not allowed.
Description
No user entry needed. Default = connected terminal.
Enter <TERMINAL>-<BANK>-<SLOT> to identify the
facilities for which performance-monitoring registers
will be initialized.
Default = ALL.
No user entry needed.
Default = 0.
B-17