Selector
No.
1
ON-duration of the scanning light
|
source at room temperature
(Not used.)
3
4
I-FAX Relay Report
5
|
Modem attenuator
8
Note: Selectors 1 through 3 are applicable to CCD models.
• Selectors 1 through 3: ON-duration of the scanning light source at room temperature (Not used.)
If the scanning operation is started when the scanning light source is off, then it will come
on for scanning. These selectors determine how long the light source is ON after scanning.
If these selectors are set to "1, 1, 1," the light source goes off immediately after the
scanning sequence.
• Selectors 5 through 8: Modem attenuator
These selectors are used to adjust the transmitting level of the modem when the reception
level at the remote station is improper due to line loss. This function applies to super G3
protocol signals.
WSW41
(ON-duration of the scanning light source)
Function
App. 4-46
Setting and Specifications
No. 1 2 3
0 0 0
: 16 hours
0 0 1
: 24 hours
0 1 0
: 12 hours
0 1 1
: 8 hours
1 0 0
: 4 hours
1 0 1
: 2 hours
1 1 0
: 10 minutes
1 1 1
: 0 minute
0: ON
No. 5 6 7 8
0 0 0 0
:
0 0 0 1
:
0 0 1 0
:
0 0 1 1
:
0 1 0 0
:
|
1 1 1 1
:
1: OFF
-10 dBm
-11 dBm
-12 dBm
-13 dBm
-14 dBm
|
-25 dBm