20 July 2005
When you Reassemble the Fusing Unit
The 4 x stripper pawls must be put in the correct position before you can
reassemble the fusing unit. Do the following procedure before you put the fusing
unit back to the fusing unit assembly.
1. Snap the 4 x stripper pawls [A] out of the left and right side stripper pawl holder
slots (shown in red circles below).
2. Put the top part of the fusing unit onto the bottom part of the fusing unit.
3. Place the 4 x stripper pawls [A] back into the stripper pawl holder slots (shown
with two red arrows in the illustration below).
4. Push the sides of the stripper pawls securely into the stripper pawl holder slots.
5. Reassemble the rest of the fusing unit and set is back into the machine again.
[A]
[A]
3-21
FUSING UNIT
G144R901.TIF
G144R902.TIF