11. CLI Commands

11.4 Commands

11.4.1 Guidelines

• The general form of a command is command name + parameter 1 + parameter 2 + control 1 + control 2.
• Always specify the command name first, followed by one or more parameters, and then the controls, if any.
• If you have two or more parameters, the order of these parameters among themselves does not affect the
result of the operation. For example, both of the following commands execute the same task:
o command name + parameter 1 + parameter 2
o command name + parameter 2 + parameter 1
• If you have two or more controls, the order of these controls among themselves does not affect the result of the operation.
For example, both of the following commands execute the same task:
o command name + control 1 + control 2
o command name + control 2 + control 1
• The command syntax uses the following notations:
Notation
+
[ ]
<argument>
|

11.4.2 Switching Sources

To switch source on a display, type the command in this format: sw + i<port> + [o<port>] + on|off + \r\n
Control
i<port>
o<port>
on
off
\r\n
Examples:
• To switch the source to a B162-001-POE transmitter with the IP address of 10.0.90.11 to the B162-100-POE receiver
you used to make the CLI connection, type sw i10.0.90.11 on
• To switch the source to a B162-001-POE transmitter with the ID of 1 on a B162-100-POE receiver with the ID of 5,
type sw i1 o5 on
• To stop source transmission from a B162-001-POE transmitter with the IP address of 10.0.70.43 to a B162-100-POE
receiver with the ID of 3, type sw i10.0.70.43 o3 off
Description
Indicates a space in the command.
Indicates optional items. Only type the information inside the brackets,
not the brackets themselves.
Indicates the name of the value the user must provide. Only type the
information within the angle brackets, not the brackets themselves.
Indicates 2 or more mutually exclusive choices in a command line.
Only type one choice in the command line, not the symbol.
Description
Indicates the device ID, MAC address or IP address of the input device
(B162-001-POE).
Indicates the device ID, MAC address or IP address of the output device
(B162-100-POE). Omit this variable to assign the specified source to the
display you used to make the CLI connection.
Enables the specified command.
Disconnects from the current connection.
Ends the command.