Load Default Settings; Firmware Version - Sungrow SG2K5TL User Manual

Pv grid-connected inverter
Table of Contents

Advertisement

SG2K5TL/SG3KTL/SG4KTL-31
10.11

Load Default Settings

If "Load default" is performed, all running information and historical records
will unrecoverable cleared off. And all parameters not including protective
parameters and time will return to the default values.
1. Press ENTER to enter general control screen from the default screen.
2. Press ▼ to navigate arrow-pointer to "Set-param" and then press ENTER.
3. Press ► to move cursor to the right and press button ▼ to set password 1111. And
press ENTER to enter into parameters settings.
4. Press ▼ to navigate arrow-pointer to "Sys-param" and then press ENTER.
5. Press ▼ to navigate arrow-pointer to "Load default" and then press ENTER.
6. Press ► to move right and press ▼ to input the password 1111.
7 Inverter will begin to return to the factory value after pressing ENTER.
10.12

Firmware Version

1. Press ENTER to enter general control screen from the default screen.
2. Press ▼ to navigate arrow-pointer to "Set-param" and then press ENTER.
3. Press ► to move cursor to the right and press button ▼ to set password 1111. And
press ENTER to enter into parameters settings.
4. Press ▼ to navigate arrow-pointer to "Sys-param" and then press ENTER.
5. Press ▼ to navigate arrow-pointer to "Firmware Version" and then press ENTER to
get the version information.