installation

Conversion to Rear Vent

Note: This conversion must be done prior to the unit being
placed in position.
The unit comes equipped as a top vent unit. These instruc-
tions are to be used only if the unit is going to be rear
vented.
1. Remove the collar trim piece from the unit by removing 6 screws.
Collar trim piece
Diagram 1
2. Remove the intake over plate from the rear by removing the top 2 screws
and loosening the bottom 2 screws.
Diagram 2
Diagram 3
3. Remove the exhaust cover plate from the rear by removing the top 4 screws
and loosening the bottom 2 screws.
Diagram 4
42 | Grandview
G600C Gas Fireplace
®
Hidden screw
Diagram 5
4. Remove the intake collar from the top by removing 4 screws.
Hidden screw
Diagram 6
Diagram 7
5. Remove the exhaust collar from the top by removing the front 4 screws and
loosening the screws closest to the back of the unit.
Diagram 8
Diagram 9