Mitsubishi Electric MELSEC-A0J2H Series Handbook page 66

Table of Contents

Advertisement

3
I/O MODULES REPLACEMENT
Specifications
Mechanical life
Electrical life
OFFON
Response
time
ONOFF
External
Voltage
supply
power
(Relay coil
Current
driving
power)
Specifications
Common terminal
arrangement
Operation indication
Current consumption
External connection
method
Applicable wire size
Applicable solderless
terminal
External dimensions
Weight
*1
Use the QX70 when using 12VDC.
*2
Check the specifications of the sensor or switches to be connected to the QX40.
3
- 25
A0J2-E56DR output
specifications
20 million times or more
Rated switching
Rated switching voltage/current
voltage/current load
200,000 times or more
(COS=0.7) 100,000 times or
(COS=0.7) 300,000 times or
200VAC 1.5A, 240VAC 1A
(COS=0.7) 200,000 times or
more
(COS=0.35) 100,000 times or
200VAC 0.75A, 240VAC 0.5A
(COS=0.35) 200,000 times or
200VAC 0.3A, 240VAC 0.15A
more
(COS=0.35) 300,000 times or
24VDC 1A, 100VDC 0.1A
(L/R=7ms) 200,000 times or
more
10ms or less
12ms or less
24VDC±10%
Ripple voltage 4Vp-p or less
230mA
(24VDC All points are ON.)
A0J2-E56DR
8 points/common
(Common terminal:
TB9, TB19, TB29)
Available (Turning ON the output
turns LED ON)
0.230A (TYP. All points are ON.)
36-point terminal block
connector
(M3 × 6 screws) 2 pieces
2
0.75 to 2mm
1.25-3, 1.25-YS3A,
2-S3, 2-YS3A,
(Sleeved solderless terminals
V1.25-3, V1.25-YS3A,
V2-S3, V2-YS3A
250(H) × 190(W) × 41(D)mm
98(H) × 27.4(W) × 90(D)mm × 4
1.08kg
: Compatible,
QY10
Compatibility
20 million times or more
load
100,000 times or more
200VAC 1.5A, 240VAC 1A
more
200VAC 0.4A, 240VAC 0.3A
more
200VAC 1A, 240VAC 0.5A
more
more
24VDC 1A, 100VDC 0.1A
(L/R=7ms) 100,000 times or
more
24VDC 0.3A
100VDC 0.03A(L/R = 7ms)
300,000 times or more
10ms or less
12ms or less
QX40/QY10
Compatibility
16 points/common
(Common terminal: TB17)
ON indication (LED)
0.05 × 2+0.43 × 2=0.96A
(TYP. All points are ON.)
18-point terminal block
(M3 × 6 screws) 4 pieces
2
0.3 to 0.75mm
core
(Outside diameter: 2.8mm or
less)
R1.25-3
cannot be used.)
0.16 × 2 +0.22 × 2 = 0.76kg
: Partially changed, × : Incompatible
Precautions for replacement
Reduce the exchange intervals of
the modules as Mechanical/
Electrical Life is cut to about half.
External supply power is not
required.
Precautions for replacement
As the common changes from
three commons to a common,
wiring with a different voltage for
each common is not possible.
Review current capacity since
current consumption is increased.
×
×
Wiring change is required.
×
×
The dimensions are different.

Advertisement