Mitsubishi Electric MELSEC-A0J2H Series Handbook page 175

Table of Contents

Advertisement

10
REPLACING THE SPECIAL FUNCTION MODULE
(c) Programmable controller CPU I/O signal comparison
I/O signal is different, so the sequence program must be changed.
Refer to the Digital-Analog Converter Module User's Manual for details regarding the I/O signals and
sequence program.
A0J2-62DA
Device
Signal name
No.
X0
Watchdog timer error
X1
D/A conversion READY
X2
X3
X4
X5
X6
X7
X8
X9
XA
XB
XC
XD
Use prohibited
XE
XF
X10
X11
X12
X13
X14
X15
X16
X17
X18
X19
X1A
X1B
X1C
X1D
X1E
X1F
Device
Signal name
No.
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y8
Y9
YA
YB
Use prohibited
YC
YD
YE
YF
Y10
Y11
Y12
Y13
Y14
Y15
Y16
Y17
Y18
Y19
Y1A
Y1B
Output enable
Y1C
Y1D
Use prohibited
Y1E
Y1F
Q62DAN
Device
Signal name
No.
X0
Module READY
X1
X2
X3
Use prohibited
X4
X5
X6
X7
High resolution mode
X8
condition flag
Operating condition
X9
setting complete flag
Offset gain setting mode
XA
condition flag
Channel change
XB
completed flag
Setting change
XC
completed flag
Synchronous output mode
XD
condition flag
XE
Use prohibited
XF
Error occurrence flag
Device
Signal name
No.
Y0
Use prohibited
CH1 Output enable/
Y1
disable flag
CH2 Output enable/
Y2
disable flag
Y3
Y4
Y5
Use prohibited
Y6
Y7
Y8
Operating condition
Y9
setting request
YA
User range write request
YB
Channel change request
YC
Setting change request
Synchronous output
YD
request
YE
Use prohibited
YF
Error clear request
10
- 12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec q series

Table of Contents