Mitsubishi Electric MELSEC-A0J2H Series Handbook page 182

Table of Contents

Advertisement

10
REPLACING THE SPECIAL FUNCTION MODULE
(d) Buffer memory address comparisons
Buffer memory allocation is different, so the sequence program must be changed.
Refer to the High-Speed Counter Module User's Manual for details regarding the buffer memory and
sequence program.
Address
CH1
CH2
0
0
1
33
Preset value write (lower/middle)
(2)
(34)
Preset value write (upper)
3
35
Mode register
4
36
Present value read (lower/middle)
(5)
(37)
Present value read (upper)
6
38
Set value read/write (lower/middle)
(7)
(39)
Set value read/write (upper)
10
- 19
A0J2-D61S1
Name
Read/Write
R/W
R/W
Address
CH1
CH2
0
32
Preset value setting
1
33
W
2
34
Present value
3
35
4
36
Coincidence output point No. 1
R
setting
5
37
6
38
Coincidence output point No. 2
7
39
setting
8
40
Overflow detection
9
41
Counter function selection setting
10
42
Sampling/periodic setting
11
43
Sampling/periodic counter flag
12
44
Latch count value
13
45
14
46
Sampling count value
15
47
16
48
Periodic pulse count previous value
17
49
18
50
Periodic pulse count present value
19
51
20
52
Ring counter lower minimum value
21
53
22
54
Ring counter maximum value
23
55
24
56
to
to
System area
31
63
QD62/QD62-H02
Name
Read/Write
(L)
(H)
(L)
(H)
(L)
(H)
(L)
(H)
(L)
(H)
(L)
(H)
(L)
(H)
(L)
(H)
(L)
(H)
(L)
(H)
R/W
R
R/W
R
R/W
R
R/W