REPLACING THE SPECIAL FUNCTION MODULE
(b) Functional comparisons
Item
Machine OPR function
(OPR method)
JOG operation
Manual pulse generator connectibility is
Manual pulse generator's movement per
Manual pulse generator
operation
1 time
positioning
(terminate)
n-time
positioning
Positioning
(continue)
data
Change the
speed and
continue
positioning
(pattern
change)
Present value change
M code output function
M code comment
Speed change function
Compensation
Position
control
Stroke limit
JOG operation,
function
manual pulse
generator
operation
Error display
History data
(start, error, warning)
A0J2-D71
Available (3 methods)
Available
Available
one pulse generator/axis.
pulse
-1
1 to 100000 (× 10
µm)
-5
1 to 100000 (× 10
inches)
-1
1 to 100000 (× 10
degrees)
1 to 100 (pulses)
Available
Available
Available
Available
Available
Available
Available
Backlash compensation, error
compensation
Available
None
None
None
: Compatible,
QD75P2
Available (6 methods)
Available
Available
Manual pulse generator connectibility is one
pulse generator/module.
Pulse input magnification for manually
generated pulse: 1 to 100 times
Available
Available
Available
Available
Available
None
Available
Electronic gear, backlash compensation,
near pass
Available
Available
(Limit check can be selected on or off.)
Error LED
Available (3 types and 16 data/module)
: Partially changed, × : Incompatible
Compat-
Precautions for
ibility
replacement
• On the QD75P2 the
manual pulse generator
cannot be used
independently on each
axis. If the manual pulse
generator must be
connected to each axis,
use the 1-axis module.
• The A0J2D71 and
QD75P2 differ in the
specifications of manual
pulse inputs, so before
connecting a manual
pulse generator to the
QD75P2, confirm the
specifications of the
pulse generator.
• If not using the unit
pulse on the QD75P2,
the magnification from
the pulse input from the
manual pulse generator
will become smaller.
QD75P2 has no M code
×
comment function.
The QD752P2 does not
have the error
compensation function.
Use the electronic gear
function instead.
At default, the limit check is
on.
10
- 24