Mitsubishi Electric MELSEC-A0J2H Series Handbook page 44

Table of Contents

Advertisement

3
I/O MODULES REPLACEMENT
A0J2H models to be discontinued
Product name
Output module
3
- 3
Model name
Model name
*1
QY50
A0J2-E24T
A0J2E-E24T
QY80
Alternative Q series models
Remarks (restrictions)
1) Change in external wiring: Required
2) Change in the number of modules: Required
(2 modules necessary)
3) Change in a program
Change in the number of occupied I/O points: Required (64
points  16 points × 2)
4) Change in specifications
Change in rated output voltage: Not required
Change in rated output current: Not required
5) Change in functions: Not required
1) Change in external wiring: Required
2) Change in the number of modules: Required
(2 modules necessary)
3) Change in a program
Change in the number of occupied I/O points: Required (64
points  16 points × 2)
4) Change in specifications
Change in rated output voltage: Not required
Change in rated output current: Required (output 0.8A  0.5A)
5) Change in functions: Not required