I/O Signal Comparison To Programmable Controller Cpu - Mitsubishi Electric MELSEC-A/QnA Series Handbook

Table of Contents

Advertisement

6
HIGH-SPEED COUNTER MODULE REPLACEMENT

6.2.3 I/O signal comparison to programmable controller CPU

Sequence program change is required as the I/O signals differ.
For details of the I/O signals or sequence program, refer to the High-Speed Counter Module User's
Manual.
Device
Signal name
No.
X0
CH1 Counter value greater
CH1 Counter value
X1
coincidence
X2
CH1 Counter value less
CH1 External preset request
X3
detection
X4
CH2 Counter value greater
CH2 Counter value
X5
coincidence
X6
CH2 Counter value less
CH2 External preset request
X7
detection
X8
X9
XA
XB
XC
XD
XE
XF
X10
X11
X12
Not used
X13
X14
X15
X16
X17
X18
X19
X1A
X1B
X1C
X1D
X1E
X1F
AD61
Device
Signal name
No.
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Not used
Y8
Y9
YA
YB
YC
YD
YE
YF
CH1 Coincidence signal
Y10
reset command
Y11
CH1 Preset command
CH1 Coincidence signal
Y12
output enable command
Y13
CH1 Down count command
Y14
CH1 Count enable
CH1 Present value read
Y15
request
CH1 External preset
Y16
detection reset command
CH2 Coincidence signal
Y17
reset command
Y18
CH2 Preset command
CH2 Coincidence signal
Y19
output enable command
Y1A
CH2 Down count command
Y1B
CH2 Count enable
CH2 Present value read
Y1C
request
CH2 External preset
Y1D
detection reset command
Y1E
Not used
Y1F
QD62-H01
Device
Signal name
No.
X0
Module READY
CH1 Counter value large
X1
(Point No.1)
CH1 Counter value
X2
coincidence (Point No.1)
CH1 Counter value small
X3
(Point No.1)
CH1 External preset request
X4
detection
CH1 Counter value large
X5
(Point No.2)
CH1 Counter value
X6
coincidence (Point No.2)
CH1 Counter value small
X7
(Point No.2)
CH2 Counter value large
X8
(Point No.1)
CH2 Counter value
X9
coincidence (Point No.1)
CH2 Counter value small
XA
(Point No.1)
CH2 External preset request
XB
detection
CH2 Counter value large
XC
(Point No.2)
CH2 Counter value
XD
coincidence (Point No.2)
CH2 Counter value small
XE
(Point No.2)
XF
Fuse broken detection flag
Device
Signal name
No.
CH1 Coincidence signal
Y0
No.1 reset command
Y1
CH1 Preset command
CH1 Coincidence signal
Y2
enable command
Y3
CH1 Down count command
Y4
CH1 Count enable command
CH1 External preset
Y5
detection reset command
CH1 Counter function
Y6
selection start command
CH1 Coincidence signal
Y7
No.2 reset command
CH2 Coincidence signal
Y8
No.1 reset command
Y9
CH2 Preset command
CH2 Coincidence signal
YA
enable command
YB
CH2 Down count command
YC
CH2 Count enable command
CH2 External preset
YD
detection reset command
CH2 Counter function
YE
selection start command
CH2 Coincidence signal
YF
No.2 reset command
6
- 7