7
POSITIONING MODULE REPLACEMENT
Changed functions
Command in-position function
Positioning start No.
Block start data
Start history
Detailed parameters
"
Software stroke limit valid/
Pr.15
invalid setting"
The command in-position width is expanded.
• AD75M: 1 to 32767000
• QD75M: 1 to 2147483647
7004 to 7010 (block start designation) and 8000 to 8049 (indirect designation) are deleted.
With QD75M, number of blocks has been change to 5 (7000 to 7004).
(With the AD75M, this data is called "Positioning start information".)
The configuration of start information and start No. is changed so that the start No. can be directly
checked.
0
(Factory setting)
1
Change description
AD75M
Software stroke limits invalid for
manual operation
Software stroke limits valid for
manual operation
QD75M
Software stroke limits valid for
manual operation
Software stroke limits invalid for
manual operation
7
- 26