7
POSITIONING MODULE REPLACEMENT
Changed functions
Command in-position function
Positioning start No.
Block start data
Start history
Detailed parameters
"
Software stroke limit valid/
Pr.15
invalid setting"
The command in-position width is expanded.
• AD75M: 1 to 32767000
• QD75M: 1 to 2147483647
7004 to 7010 (block start designation) and 8000 to 8049 (indirect designation) are deleted.
With QD75M, number of blocks has been change to 5 (7000 to 7004).
(With the AD75M, this data is called "Positioning start information".)
The configuration of start information and start No. is changed so that the start No. can be directly
checked.
0
(Factory setting)
1
Change description
AD75M
Software stroke limits invalid for
manual operation
Software stroke limits valid for
manual operation
QD75M
Software stroke limits valid for
manual operation
Software stroke limits invalid for
manual operation