Remote Operation

Install 7-Segment Display Panel
The 7-segment display panel can be removed from the inverter and installed in a different location in the vehicle for
remote control and monitoring.
1. Unscrew the two screws that hold the panel in using a 3/32" Allen wrench.
2. Disconnect the RJ45 connector from the back of the remote panel.
3. Install the RJ45 connector to the backside of the replacement RJ45 cover plate.
WARNING: Mount the RJ45 cover plate on the inverter with the two screws provided in the remote extension
kit (8-32x3/8"). DO NOT USE the screws that held the display to mount the RJ45 cover plate. Using any other
screw type or length than that provided in the kit may damage the inverter and/or harm the installer. Tighten
the screws to 16–17 inch-pounds.
4. Connect the extension cable to the RJ45 jack.
5. Route the cable through the vehicle to the desired location.
NOTE: Avoid routing the RJ45 connector around high current power cables.
6. Install the remote display panel at the desired new interior location using installer supplied #8 screws and
connect the extension cable to it.
To mount remotely, the 7-Seg Display panel will require the mounting hole and screw positions shown below:
Page 16
Figure 7 Seven-Segment Display Hole Pattern