REMOTE INVERTER ON/OFF SWITCH

Remote Inverter ON/OFF Switch – Customer Supplied
Two types of remote switches may be used to control the inverter/charger.
They are momentary or snap switches. However, the type of switch used can
only be used in specific circumstances. For non "-R" suffix versions, a
momentary switch must be used. For remote only "-R" suffix versions, a snap
switch must be used. If a snap switch is used in place of a momentary switch,
the inverter may not respond correctly.
In remote only mode, the snap switch will turn the inverter on and off when in
inverter mode. When in charger mode, it will switch the inverter state between
off and standby.
In non-remote only mode, the momentary switch will toggle the inverter state
between on and off, or standby and off while in charge mode.
The remote switch may be customer supplied or ordered separately from the
factory. Mount the remote switch in a convenient location. Using 18-gauge wire
and an insulated ¼" female faston, wire between the "Remote ON/OFF"
connection on the left side of the inverter. Wire from the remaining connection
on the remote switch to the battery positive (+) terminal. Be sure to install a 5-
amp in-line fuse in series within 10 inches from the positive (+) terminal of the
battery.
CONNECT TO "REMOTE 
CONNECT TO "REMOTE 
ON/OFF" TAB
ON/OFF" TAB
FUSE
FUSE
12.6Vdc
12.6Vdc
BATTERY
BATTERY
 
Figure 8 - 12LP15R shown with snap switch
 
 
REMOTE 
REMOTE 
ON/OFF 
ON/OFF 
SWITCH
SWITCH
14