Branch Circuit Rating (Bcr) Max Limit With The 7-Seg Display Panel; Battery Type And Profile With The 7-Seg Display Panel - Sensata dimensions 12NP18 Owner's Manual

Dc to ac power inverter/charger
Table of Contents

Advertisement

Branch Circuit Rating (BCR) Max Limit with the 7-Seg Display Panel

The BCR max limit sets the max limit that is adjustable by the 7-Seg Display. For example, if the limit is set to 15 A,
the user may only select 0, 5, 10, or 15 amps. If the limit is set to 30 A, the user may then select from 0–30 amps in
5 A increments.
The connected 7-Seg Display will overwrite any other BCR value programmed into the inverter/charger by any
other device.
The 7-Seg Display Panel can be used to adjust the BCR maximum limit. To adjust the 15 A default setting, the 7-Seg
Display Panel must be reconfigured. Follow these instructions to adjust the BCR maximum limit:
1. Press and hold "Menu" and "Display/Select" for 5–10 seconds to enter configuration mode. The green "Fault"
LED will come on.
2. Press "Display/Select" once. The current BCR maximum limit setting will be displayed.
3. Press "Display/Select" to cycle through the available setting options (15, 20, or 30 amps) until the desired
setting is displayed.
4. Press "Menu" to confirm the desired setting. The chosen value will be displayed:
AC In Nt 30A
5. Press "Menu" twice to exit configuration mode. The green "Fault" LED will no longer be on.

Battery Type and Profile with the 7-Seg Display Panel

The 7-Seg Display Panel can be used to adjust the battery type. To adjust the setting, the 7-Seg Display Panel must
be reconfigured. Follow these instructions to adjust the battery type:
Battery Type
1. Press and hold "Menu" and "Display/Select" for 5–10 seconds to enter configuration mode. The green "Fault"
LED will come on.
2. Press "Menu" twice. The current battery type setting will be displayed.
3. Press "Display/Select" to cycle through the available setting options (FLd, GEL, AGM, and LFP) until the
desired setting is displayed.
4. Press "Menu" to confirm the desired setting. The chosen value will be displayed:
5. Press "Menu" twice to exit configuration mode. The green "Fault" LED will no longer be on.
Battery Profile
1. Press and hold "Menu" and "Display/Select" for 5–10 seconds to enter configuration mode. The green "Fault"
LED will come on.
2. Press "Menu" three times. The current battery profile setting will be displayed.
3. Press "Display/Select" to cycle through the available setting options until the desired setting is displayed.
4. Press "Menu" to confirm the desired setting. The chosen value will be displayed:
5. Press "Menu" twice to exit configuration mode. The green "Fault" LED will no longer be on.
Page 34
12NP Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dimensions 12np20Dimensions 12np24Dimensions 12np30

Table of Contents