NP Control Board Pinout

An additional switch may be installed as an optional way to enable the inverter. Enable remote operation by
installing a switch between between the pin 4 and 6. The installed switch must be rated for 80 V minimum.
Inverter
Request
ACC / Remote
(RJ12)
Battery
Temperature
Sensor (RJ12)
CAN Bus (DB9)
SYNC/STACK
(RJ45) - Not Yet
Supported
Page 18
GND
CAN H
GND
V
batt
CAN L
Figure 9 Pinout
Board Pinout
PIN 1 & 3
PIN 2
PIN 4
PIN 5
PIN 6
PIN 1
PIN 2 & 5
PIN 3
PIN 4 & 6
PIN 1, 4, 5, 6, 8, & 9
PIN 2
PIN 3
PIN 7
PIN 1 & 2
PIN 3 & 4
PIN 5 & 6
PIN 7
PIN 8
Table 3 Pinout
12NP Manual
ACC Jack
1 2 3 4 5 6
Digital Ground
CAN-H
Remote + (Output, DC Power Fused at 2 Amps)
CAN-L
Inverter Request (Input)
N/C
Sensor Signal Input
Sensor Ground
N/C
N/C
CAN-L
CAN REF, GND (N/C)
CAN-H
Digital Communication
N/C (Not Connected)
Digital Communication
N/C
Inverter Request (Output)