PAR. DESCRIPTION
Controller 2 switch-off time in the event of faulty probe.
OF2
if OF2=1 and On2=0, the controller remains off;
if OF2=1 and On2>0, the controller operates in Duty Cycle mode.
SOFT START CONTROLLER (folder 'SFt')
Value (in °C) of each subsequent increase (dynamic) of the setpoint.
dSi
0 = disabled.
dSt Time between two subsequent increases (dynamic) of the Setpoint.
Unt Unit of measurement (parameter dSt). 0 = hours; 1 = minutes; 2 = seconds.
Establishes which outputs the function must be enabled on:
Sen
0 = disabled; 1 = OUT 1; 2 = OUT 2; 3 = OUT 1 & 2
Function reactivation threshold. Establishes the threshold beyond which the
Sdi
SOFT START function is automatically reactivated.
CYCLIC CONTROLLER (folder 'cLc')
Con Output ON time.
CoF Output OFF time.
ALARMs (folder 'AL')
Parameters 'HA1/HA2' and 'LA1/LA2' , intended as the absolute temperature
Att
value or differential in relation to the setpoint.
AbS (0) = absolute value; rEL (1) = relative value.
AFd Alarm differential.
PAO Alarm override time after device is switched on following a power failure.
MODEL
RANGE
VALUE M.U. LEVEL
ALL
0...250
NTC/PTC
0.0...25.0
PT100-Tc
0.0...25.0
V/I
0...25
ALL
0...250
ALL
0/1/2
ALL
0/1/2/3
NTC/PTC
1.0...50.0
PT100-Tc
1.0...50.0
V/I
1...50
ALL
0...250
ALL
0...250
ALL
AbS/rEL
NTC/PTC
1.0...50.0
PT100-Tc
1.0...50.0
V/I
1...50
ALL
0...10
1
min
Inst
0.0
°C/°F
0.0
°C/°F
Inst
0
num
0
min
Inst
0
num
Inst
0
num
Inst
2,0
°C/°F
2.0
°C/°F
Inst
2
num
0
min
Inst
0
min
Inst
AbS
flag
Inst
2.0
°C/°F
2.0
°C/°F
Inst
2
num
0
hours
Inst