The higher value is the one that determines the evaluation. Example:
a blood pressure value of 140/80 mmHg or a value of 130/90 mmHg
indicates «blood pressure too high».

2. Using the Device for the First Time

Inserting the batteries

After you have unpacked your device, first insert the batteries. The
battery compartment 3 is at the top of the device. Insert the batteries
(2 x 1.5 V, size AAA), thereby observing the indicated polarity.

Setting the date and time

1. After the new batteries are fitted, the year number flashes in the
display. You can set the year by pressing the M-button 5. To
confirm and then set the month, press the time button 6.
2. Press the M-button to set the month. Press the time button to
confirm and then set the day.
3. Follow the instructions above to set the day, hour and minutes.
4. Once you have set the minutes and pressed the time button, the
date and time are set and the time is displayed.
5. If you want to change the date and time, press and hold the time
button down for approx. 3 seconds until the year number starts to
flash. Now you can enter the new values as described above.
4

3. Taking a Blood Pressure Measurement using this Device

Checklist for taking a reliable measurement
1. Avoid activity, eating or smoking immediately before the measurement.
2. Sit down for at least 5 minutes before the measurement and relax.
3. Always measure in a sitting position and on the same wrist. Use
the wrist which usually shows higher blood pressure values.
4. Remove any items of clothing and your watch, for example, so
that your wrist is free.
5. Always ensure that the cuff is positioned correctly, as shown in the
pictures illustrated on the short instruction card.
6. Fit the cuff comfortably but not too tight. The cuff will cover a wrist
circumference of 13.5 - 21.5 cm (5.25 - 8.5 inches).
7. Press the ON/OFF button 1 to start the measurement.
8. The LED Positioning Indicator AR is activated. Support your arm
in a relaxed position with the device at the same height as your
heart, move your arm until the LED light is at its brightest and
appears to be in the center of the indicator.
9. After 5 seconds, the cuff will pump up automatically. Relax, do not
move and do not tense your arm muscles until the measurement
result is displayed. Breathe normally and do not talk.
10.When the correct pressure is reached, the pumping stops and the
pressure falls gradually. If the required pressure was not reached,
the device will automatically pump some more air into the cuff.