Crestron Isys
TPS-3100L
MAIN MENU
This menu can also be obtained via
digital reserved join number, 17242.
CALIBRATION MENU
Operations Guide – DOC. 6291
6.4" Lectern/Wall Mounted Touchpanel

Identity Code

All equipment and user interfaces within the network require a unique identity code
(Net ID). These codes are two-digit hexadecimal numbers ranging from 03 to FE.
Refer to "Interface Menu" on page 10 for instructions on setting the unit's Net ID.
The Net ID of each unit must match an ID code specified in the SIMPL Windows
program. Refer to "Setting the Net ID in Device Settings" on page 23 for details of
the SIMPL Windows procedure.

Configuring the Touchpanel

NOTE: The only connection required to configure the touchpanel is power (+24V
and Ground). Refer to "Hardware Hookup" on page 14 for details.
To configure the unit, it may be necessary to access a series of setup screens prior to
viewing run-time screens that are loaded into the touchpanel for normal operation.
The MAIN MENU for configuring the touchpanel appears when a finger is held to
the touchscreen as power is applied. Remove your finger when the MAIN MENU
appears.
NOTE: The SETUP MODE can also be accessed through the Viewport Utility if the
touchpanel is connected to a control system via Cresnet or to a PC via RS-232 by
selecting Functions | Put Touch Panel into Setup Mode... from the Viewport
menu.
Upon entering SETUP MODE, the MAIN MENU, shown to the left, displays four
buttons: Touch Screen Calibration, Exit and Run Program, Setup, and
Diagnostics.
The Exit and Run Program button verifies that all of the setup information has
been saved to EEPROM and displays the main page that has been programmed into
your system. The remaining buttons on the MAIN MENU open other menus, which
are discussed in subsequent paragraphs.
Calibration Menu
Calibration of the touchscreen is required if the active touch area of a button does
not coincide with the button's image. Select the Touch Screen Calibration button to
display the CALIBRATION MENU, shown to the left. The CALIBRATION MENU
offers the choice to initiate calibration with the Perform Calibration button or
return to the previous screen with the Return button. Choose an option by touching
the correct button.
If you proceed to calibrate the touchpanel, the screen displays the message "Touch
Lower Right" centered on the panel with a cross hair in the lower right corner.
Touch the center of the cross hair in the corner of the screen to initiate calibration.
Another message, "Touch Lower Left", appears with a cross hair in the correct
corner. Touch the center of the cross hair in the corner of the screen. A final
message, "Touch Upper Left", appears with a cross hair in the correct corner. Touch
the center of the cross hair in the corner of the screen to conclude calibration and
return to the MAIN MENU.
NOTE: When touching the screen during calibration, be as accurate as possible.
Use the tip of a capped pen or the eraser end of a pencil. To cancel calibration and
return to the CALIBRATION MENU without saving calibration data, create a
calibration error by touching the screen in the same spot for each calibration point.