Crestron Isys TPS-3100L Operation Manual page 39

6.4 inch lectern/wall mounted touchpanel
Hide thumbs Also See for Isys TPS-3100L:
Table of Contents

Advertisement

®
Crestron Isys
TPS-3100L
Operations Guide – DOC. 6291
6.4" Lectern/Wall Mounted Touchpanel
Setup | Communications Settings Command
3. Select RS-232 as the connection type. Verify that an available COM port
(COM 1 is shown after this step) is selected, and that all communication
parameters and necessary options from the "Port Settings" window are
selected as shown after this step. Click the OK button to save the settings
and close the window.
"Port Settings" Window
NOTE: The parameters shown in the previous illustration are the port settings for a
2-Series control system. Consult the Operations Guide for the control system being
used for exact parameter selection. Default communication parameters for the
touchpanel are 115200, 8 bit, parity none, stop bit 1, XON/XOFF off, RTS/CTS off.
NOTE: If connecting to the touchpanel through a control system, the baud rate may
need to be set to 38400 baud (Cresnet speed) for a successful transfer.
6.4 Inch Lectern/Wall Mount Touchpanel: Crestron Isys® TPS-3100L • 35