Crestron TPS-1700 Operation Manual
Crestron TPS-1700 Operation Manual

Crestron TPS-1700 Operation Manual

Wired 5.7 inch tabletop touchpanel
Hide thumbs Also See for TPS-1700:

Advertisement

Quick Links

Crestron TPS-1700
Isys
Wired 5.7 Inch Tabletop Touchpanel
®
Operations Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TPS-1700 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Crestron TPS-1700

  • Page 1 Crestron TPS-1700 Isys Wired 5.7 Inch Tabletop Touchpanel ® Operations Guide...
  • Page 2 This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2004 Crestron Electronics, Inc.
  • Page 3: Table Of Contents

    Crestron TPS-1700 Contents ® Isys Wired 5.7 Inch Tabletop Touchpanel: TPS-1700 Introduction ... 1 Functions and Features ... 1 Specifications ... 2 Physical Description... 3 Industry Compliance ... 4 Setup ... 5 Network Wiring... 5 Identity Code ... 6 Configuring the Touchpanel... 6 Hardware Hookup ...
  • Page 5: Isys ® Wired 5.7 Inch Tabletop Touchpanel: Tps-1700

    Functional Summary NOTE: The TPS-1700 is supplied with an optional bezel, ten membrane switches, and ten black pushbuttons (blank), five for each side of the LCD screen. You can use these buttons to access any frequently used commands.
  • Page 6: Specifications

    Overall Dimensions Weight The latest versions can be obtained from the Downloads | Software Updates section of the Crestron website (www.crestron.com). Refer to NOTE after last footnote. Crestron 2-Series control systems include the AV2 and PRO2. Consult the latest Crestron Product Catalog for a complete list of 2-Series control systems.
  • Page 7: Physical Description

    FTP site). Physical Description The touch-sensitive viewing screen is located on the front of the TPS-1700. The electronic hardware is housed in a black and silver molded plastic enclosure. Connection to the control system is via a 6-pin RJ-11 connector mounted on the bottom of the unit base.
  • Page 8: Industry Compliance

    As of the date of manufacture, this unit has been tested and found to comply with specifications for CE marking and standards per EMC and Radio Communications Compliance Labeling (N11785). ® 4 • Isys Wired 5.7 Inch Tabletop Touchpanel: TPS-1700 Crestron TPS-1700 Operations Guide - DOC. 6223A...
  • Page 9: Setup

    R = Resistance (refer to table below). L = Length of run (or chain) in feet. PF = Power factor of entire run (or chain). RESISTANCE (R) WIRE GAUGE Doubled CAT5 Tripled CAT5 ® Wired 5.7 Inch Tabletop Touchpanel: TPS-1700 • 5 Isys...
  • Page 10: Identity Code

    Windows program. Refer to “Setting the Net ID in Device Settings” on page 12 for details of the SIMPL Windows procedure. The Net ID is used when the touchpanel is wired directly to the control system during uploading a Crestron VisionTools (VT Pro-e) project or upgrading the touchpanel firmware.
  • Page 11: Setup Menu

    Disabled.”) To enable an audible tone (beep) when the touchpanel buttons are pressed, select among the Short, Med, or Long KEY CLICK ENABLE/LEN buttons to set the duration of the tone. The touchpanel responds with a corresponding signal. To disable the feature, select Click Off.
  • Page 12: Diagnostics Menu

    ENABLED and DISABLED. With ENABLED selected, the display comes on when one of the “hard” pushbuttons is pressed. With DISABLED selected, the display stays off when a “hard” pushbutton is pressed (if touchpanel was off). The default is DISABLED. Select the Return button to return to the SETUP MENU.
  • Page 13: Hardware Hookup

    Doing so can crack the screen and damage the touchpanel. The TPS-1700 touchpanel has rubber pads on the underside of its base so that it can rest on a horizontal surface. The only connection necessary is made to the 6-pin RJ-11 connector mounted in the bottom of the unit base.
  • Page 14: Programming Software

    Crestron’s True Blue Support, log in at http://www.crestron.com/accounts/login.asp. First-time users will need to establish a user account. You can create a program that allows you to set up the TPS-1700 to operate a Crestron control system using the Crestron programming tools Crestron System Builder levels of programming knowledge.
  • Page 15: Programming With Crestron System Builder

    Crestron control system. SIMPL Windows offers drag and drop functionality in a familiar Windows This section describes a sample SIMPL Windows program that includes a TPS-1700. Configuration Manager is where programmers “build” a Crestron control system by selecting hardware from the Device Library. In Configuration Manager, drag the PRO2 from the Control Systems folder of the Device Library and drop it in the upper pane of the System Views.
  • Page 16: C2Net-Device Slot In Configuration Manager

    Wired 5.7 Inch Tabletop Touchpanel C2Net-Device Slot in Configuration Manager To incorporate a TPS-1700 into the system, drag the TPS-1700 from the Touchpanels | Touchpanels (Cresnet) folder of the Device Library and drop it in System Views. The PRO2 system tree displays the touchpanel in Slot 9, with a default Net ID of 03 as shown in the following illustration.
  • Page 17: Signal Types

    TPS-1700 Symbol in Programming Manager Programming Manager is where programmers “program” a Crestron control system by assigning signals to symbols. The following graphic shows the TPS-1700 symbol in the SIMPL Windows’ Programming Manager. Detail View of the TPS-1700 in SIMPL Windows’ Programming Manager...
  • Page 18 TPS-1700 Input/Output Signals The TPS-1700 symbol provides up to 4K digital and/or analog input and output joins, up to 999 serial input and up to 127 serial output joins. The programmer selects the signal types by clicking on the appropriate button at the top of the Symbol Detail view when programming the panel.
  • Page 19: Programming With Vt Pro-E

    Crestron SIMPL Windows Symbol Guide (Doc. 6120), or the on-line help included with SIMPL Windows. Example Program An example program for the TPS-1700 is available from the Crestron FTP site (ftp://ftp.crestron.com/). Select the Examples folder and search for TPS-1700.ZIP that contains the example program, associated files, and a README.TXT file that describes the program.
  • Page 20: Optional Pushbuttons

    NOTE: To program a quick pushbutton to flip a page (change a screen) on the TPS-1700, go to the Hard Keys tab of the “Project Properties” window in VT Pro-e. Select a button from the Button drop-down list, and then select the desired page from the Page Flip drop-down list.
  • Page 21: Multibyte International Characters

    SIMPL Windows. In other words, you cannot enter Chinese character interspersed with numbers. You can enter Chinese characters or numbers in separate strings. Crestron is scheduling time to fix this in the near future and the release notes for SIMPL Windows will mention it.
  • Page 22: Uploading And Upgrading

    Other models, even from the same manufacturer, may not yield the same results. Connection to the TPS-1700 touchpanel is via a 6-pin RJ-11 connector in the base of the unit. Therefore, uploading or upgrading must be accomplished through a control system.
  • Page 23 3. Select RS-232 as the connection type. Verify that an available COM port (COM 1 is shown after this step) is selected, and that all communication parameters and necessary options from the “Port ® Wired 5.7 Inch Tabletop Touchpanel: TPS-1700 • 19 Isys...
  • Page 24: Uploading A Simpl Windows Program

    Upload via Crestron Viewport ® 20 • Isys Wired 5.7 Inch Tabletop Touchpanel: TPS-1700 Settings” window are selected as shown after this step. Click the OK button to save the settings and close the window. 4. To verify communication, select Diagnostics | Establish Communications (Find Rack).
  • Page 25 4. To verify that the program has been transferred successfully, select Diagnostics | Report Program Information. This should display a window that provides details about the current program loaded into the control system. ® Wired 5.7 Inch Tabletop Touchpanel: TPS-1700 • 21 Isys...
  • Page 26: Uploading A Vt Pro-E Project

    2. As shown after this step, select File Transfer | Send Touchpanel (alternatively, press Alt+T) from the Viewport menu. 3. As shown after this step, select the Net ID of the TPS-1700 touchpanel and then click OK. The “Touch Panel Transfer” window appears (refer to graphic on the next page).
  • Page 27: Firmware Upgrade

    “Open” Window Firmware Upgrade A firmware upgrade file has the To take advantage of all the TPS-1700 touchpanel features, it is important that the extension .csf. unit contains the latest firmware available. Therefore, please check the Crestron website (http://www.crestron.com/downloads/software_updates.asp) for the latest version of firmware.
  • Page 28 2. As shown after this step, select File Transfer | Update Touchpanel Firmware from the Viewport menu. 3. As shown after this step, select the Net ID of the TPS-1700 touchpanel and then click OK. The “Open” window appears (refer to the subsequent graphic).
  • Page 29: Problem Solving

    Crestron TPS-1700 Problem Solving Troubleshooting The table below provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. TPS-1700 Troubleshooting Touchpanel does not function. Project can not be uploaded to touchpanel.
  • Page 30: Further Inquiries

    Crestron's award winning customer service team by calling: You can also log onto the online help section of the Crestron website (www.crestron.com) to ask questions about Crestron products. First-time users will need to establish a user account to fully benefit from all available features.
  • Page 31: Appendix: Installation Of Optional Pushbuttons

    Crestron TPS-1700 Appendix: Installation of Optional Pushbuttons The TPS-1700 is supplied with ten optional pushbutton switches, blank buttons, and a bezel to accommodate the switches. As a further option, custom engraved black or silver buttons (1700C-BTNB or 1700C-BTNS) can be designed and purchased via the Crestron Engraver software.
  • Page 32: Software License Agreement

    This Agreement may only be modified by a writing signed by an authorized officer of Crestron. Updates may be licensed to You by Crestron with additional or different terms. This is the entire agreement between Crestron and You relating to the Software and it supersedes any prior representations, discussions, undertakings, communications or advertising relating to the Software.
  • Page 33 “applets” incorporated into the Software), the accompanying media and printed materials, and any copies of the Software are owned by Crestron or its suppliers. The Software is protected by copyright laws and international treaty provisions. Therefore, you must treat the Software like any other copyrighted material, subject to the provisions of this Agreement.
  • Page 34: Return And Warranty Policies

    CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended, or if it has been subjected to misuse, accidental damage, modification, or improper installation procedures.