8.3 - Function errors

Error
Cause
Motor does not run
Machine is not connected to the power
supply
Machine is not connected to the air sup-
ply
Building circuit breaker has failed
Machine fuse is defective
Drill motor power is not ON
Swing arm is swivelled in or down
Machine connected to the wrong voltage
Motor defective
Motor overheats
Machine connected to the wrong voltage Check supply voltage and compare with mo-
Boring in hard wood with too high a feed
rate
Motor hood is dirty or covered by some-
thing
Machine doesn't
Machine is not connected to the air sup-
cycle when stroke
ply
button is pressed
Air pressure is too low
Pneumatic hose is kinked or damaged
Flow control for setting the stroke speed
is closed
Stroke valve is jammed
Cylinder defective
8 - Troubleshooting
Solution
Connect machine to the power supply
Connect machine to the air supply
Reset circuit breaker or replace
Have fuse replaced by an licensed
electrician
Set drill motor power to ON
Swivel swing arm up
Check supply voltage and compare with mo-
tor data. Have checked by licensed electri-
cian
Have motor replaced by an licensed electri-
cian
tor data. Have checked by licensed electri-
cian
Reduce feed rate
Remove objects and chips in the area of the
motor hood
Connect machine to the air supply
Adjust air pressure (80-100 psi)
Check air lines
Open flow control
Replace valve or manual activator
Replace cylinder
26
Comment
none
at least 80 psi
none
See electrical dia-
gram
See point 3.1.1
See point 4.1.18
Check valve on side
of gearbox housing
See electrical dia-
gram
none
See electrical dia-
gram
See point 4.1.10
none
See point 2.2.1
See point 2.2.2
none
See point 4.1.10
none
none