3) Correcting Motor Rotation; Dust Extraction; 1) Connecting Extraction System To The Machine - BLUM MINIPRESS P Operator's Manual

Boring and insertion machine
Hide thumbs Also See for MINIPRESS P:
Table of Contents

Advertisement

2 - Machine setup

2.3.3) Correcting motor rotation

ATTENTION:
The electrical connection must be performed by a qualified electrician!
If the motor rotation is wrong:
• Set drill motor power
(3.1)
• Disconnect machine from power supply
• Switch L1 and L2 at plug connections
• Re-check the motor rotation.

2.4 - Dust extraction

2.4.1) Connecting extraction system to the machine

ATTENTION:
To minimize the risk of fire this machine must be connected to a dust
extraction system!
• Make sure that the average air velocity for the extraction system is at least 66 ft/sec.
• Insert the spiral hose with an inside diameter of approx. 3.75 inches into the receiving
tube and secure it.
12
to OFF
BA-106/1EA M53.10XX

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents